若您需要咨询产品或有任何技术问题,请通过官方电话 400 885 9050 或邮箱 info.cn@stemcell.com 与我们联系

EasySep™ Direct人T细胞分选试剂盒

直接从全血中免疫磁珠负选人T细胞

产品号 #(选择产品)

产品号 #19661_C

直接从全血中免疫磁珠负选人T细胞

产品优势

  • > 99.9%红细胞去除率,无需密度梯度离心、沉降或裂解
  • 分选获得的细胞纯度高达97%
  • 操作简单、快捷,且无需分离柱
  • 分选得到的细胞不带标记

产品组分包括

  • EasySep™ Direct人T细胞分选试剂盒(产品号 #19661)
    • EasySep™ Direct人T细胞分选抗体混合物, 2 x 2.5 mL
    • EasySep™ Direct RapidSpheres™  磁珠, 4 x 2.5 mL
  • RoboSep™ 人 T细胞分选试剂盒(含过滤     吸头)(产品号 #19661RF)
    • EasySep™ Direct人T细胞分选抗体混合物, 2 x 2.5 mL
    • EasySep™ Direct RapidSpheres™ 磁珠, 4 x 2.5 mL
    • RoboSep™ 缓冲液(产品号 #20104)
    • RoboSep™过滤吸头(产品号 #20125)x 2
New look, same high quality and support! You may notice that your instrument or reagent packaging looks slightly different from images displayed on the website, or from previous orders. We are updating our look but rest assured, the products themselves and how you should use them have not changed. Learn more
专为您的实验方案打造的产品
要查看实验方案所需的所有配套产品,请参阅《实验方案与技术文档》

总览

使用 EasySep™ Direct 人 T 细胞分选 试剂盒,可轻松高效地从人全血样本中通过免疫磁珠负选获得高纯度人 T 细胞。EasySep™技术结合单克隆抗体的特异性和免磁柱系统的简便性,已在发表的研究中广泛应用超过20年。    

在该 EasySep™ 负选过程中,非目的细胞会被抗体复合物和 EasySep™ Direct RapidSpheres™  磁珠 标记。以下非目的细胞会被特异性去除:B细胞、单核细胞、粒细胞和树突状细胞。通过EasySep™磁极将被磁珠标记的细胞与未被标记的目的细胞分离,目的细胞可通过倾倒或移液收集到新试管中,分选后的细胞可立即用于下游应用,例如细胞功能分析、流式细胞术、培养或DNA/RNA 提取          

了解更多EasySep™免疫磁珠技术的工作原理,或者如何通过RoboSep™实现全自动化免疫磁珠细胞分选。 探索更多为您的实验流程优化的产品,包括用于细胞鉴定、冷冻保存等相关试剂 。

在该 EasySep™ 负选过程中,非目的细胞会被抗体复合物和 EasySep™ Direct RapidSpheres™  磁珠 标记。以下非目的细胞会被特异性去除:B细胞、单核细胞、粒细胞和树突状细胞。通过EasySep™磁极将被磁珠标记的细胞与未被标记的目的细胞分离,目的细胞可通过倾倒或移液收集到新试管中,分选后的细胞可立即用于下游应用,例如细胞功能分析、流式细胞术、培养或DNA/RNA 提取          

了解更多EasySep™免疫磁珠技术的工作原理,或者如何通过RoboSep™实现全自动化免疫磁珠细胞分选。 探索更多为您的实验流程优化的产品,包括用于细胞鉴定、冷冻保存等相关试剂 。

在该 EasySep™ 负选过程中,非目的细胞会被抗体复合物和 EasySep™ Direct RapidSpheres™  磁珠 标记。以下非目的细胞会被特异性去除:B细胞、单核细胞、粒细胞和树突状细胞。通过EasySep™磁极将被磁珠标记的细胞与未被标记的目的细胞分离,目的细胞可通过倾倒或移液收集到新试管中,分选后的细胞可立即用于下游应用,例如细胞功能分析、流式细胞术、培养或DNA/RNA 提取          

了解更多EasySep™免疫磁珠技术的工作原理,或者如何通过RoboSep™实现全自动化免疫磁珠细胞分选。 探索更多为您的实验流程优化的产品,包括用于细胞鉴定、冷冻保存等相关试剂 。

在该 EasySep™ 负选过程中,非目的细胞会被抗体复合物和 EasySep™ Direct RapidSpheres™  磁珠 标记。以下非目的细胞会被特异性去除:B细胞、单核细胞、粒细胞和树突状细胞。通过EasySep™磁极将被磁珠标记的细胞与未被标记的目的细胞分离,目的细胞可通过倾倒或移液收集到新试管中,分选后的细胞可立即用于下游应用,例如细胞功能分析、流式细胞术、培养或DNA/RNA 提取          

了解更多EasySep™免疫磁珠技术的工作原理,或者如何通过RoboSep™实现全自动化免疫磁珠细胞分选。 探索更多为您的实验流程优化的产品,包括用于细胞鉴定、冷冻保存等相关试剂 。

磁体兼容性
• EasySep™ Magnet (Catalog #18000) • “The Big Easy” EasySep™ Magnet (Catalog #18001) • Easy 50 EasySep™ Magnet (Catalog #18002) • EasyEights™ EasySep™ Magnet (Catalog #18103) • RoboSep™-S (Catalog #21000)
 
亚型
细胞分选试剂盒
 
细胞类型
T 细胞
 
种属

 
样本来源
Whole Blood
 
筛选方法
Negative
 
应用
细胞分选
 
品牌
EasySep,RoboSep
 
研究领域
免疫,细胞治疗开发
 

实验数据

Isolated T cells from whole blood obtained using EasySep™ Direct human T cell isolation kit

Figure 1. Typical EasySep™ Direct Human T Cell Isolation Profile

Starting with human whole blood from normal healthy donors, the typical T cell (CD3+) content of the non-lysed final isolated fraction is 95.3 ± 1.4% (gated on CD45) or 94.9 ± 1.5% (not gated on CD45). In the example above, the T cell (CD3+) content of the lysed whole blood start sample and non-lysed final isolated fraction is 33.0% and 95.0% (gated on CD45), respectively, or 33.0% and 94.9% (not gated on CD45), respectively. The starting frequency of T cells in the non-lysed whole blood start sample above is 0.059% (data not shown).

产品说明书及文档

请在《产品说明书》中查找相关支持信息和使用说明,或浏览下方更多实验方案。

Document Type
Product Name
Catalog #
Lot #
Language
Catalog #
19661RF
Lot #
All
Language
English
Catalog #
19661
Lot #
All
Language
English
Document Type
Safety Data Sheet 1
Catalog #
19661RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Catalog #
19661RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 1
Catalog #
19661
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Catalog #
19661
Lot #
All
Language
English

应用领域

本产品专为以下研究领域设计,适用于工作流程中的高亮阶段。探索这些工作流程,了解更多我们为各研究领域提供的其他配套产品。

相关材料与文献

技术资料 (16)

常见问题

Can EasySep™ be used for either positive or negative selection?

Yes. The EasySep™ kits use either a negative selection approach by targeting and removing unwanted cells or a positive selection approach targeting desired cells. Depletion kits are also available for the removal of cells with a specific undesired marker (e.g. GlyA).

How does the separation work?

Magnetic particles are crosslinked to cells using Tetrameric Antibody Complexes (TAC). When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a separate fraction.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Can EasySep™ be used to isolate rare cells?

Yes. We recommend a cell concentration of 2x108 cells/mL and a minimum working volume of 100 µL. Samples containing 2x107 cells or fewer should be suspended in 100 µL of buffer.

Are the EasySep™ magnetic particles FACS-compatible?

Yes, the EasySep™ particles are flow cytometry-compatible, as they are very uniform in size and about 5000X smaller than other commercially available magnetic beads used with column-free systems.

Can the EasySep™ magnetic particles be removed after enrichment?

No, but due to the small size of these particles, they will not interfere with downstream applications.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

For positive selection, can I perform more than 3 separations to increase purity?

Yes, the purity of targeted cells will increase with additional rounds of separations; however, cell recovery will decrease.

How does the binding of the EasySep™ magnetic particle affect the cells? is the function of positively selected cells altered by the bound particles?

Hundreds of publications have used cells selected with EasySep™ positive selection kits for functional studies. Our in-house experiments also confirm that selected cells are not functionally altered by the EasySep™ magnetic particles.

If particle binding is a key concern, we offer two options for negative selection. The EasySep™ negative selection kits can isolate untouched cells with comparable purities, while RosetteSep™ can isolate untouched cells directly from whole blood without using particles or magnets.

文献 (1)

Raman-based spectrophenotyping of the most important cells of the immune system. A. Borek-Dorosz et al. Journal of advanced research 2022 nov

Abstract

INTRODUCTION Human peripheral blood mononuclear cells (PBMCs) are a heterogeneous population of cells that includes T and B lymphocytes. The total number of lymphocytes and their percentage in the blood can be a marker for the diagnosis of several human diseases. Currently, cytometric methods are widely used to distinguish subtypes of leukocytes and quantify their number. These techniques use cell immunophenotyping, which is limited by the number of fluorochrome-labeled antibodies that can be applied simultaneously. OBJECTIVE B and T lymphocytes were isolated from peripheral blood obtained from healthy human donors. METHODS The immunomagnetic negative selection was used for the enrichment of B and T cells fractions, and their purity was assessed by flow cytometry. Isolated cells were fixed with 0.5% glutaraldehyde and measured using confocal Raman imaging. K-means cluster analysis, principal component analysis and partial least squares discriminant methods were applied for the identification of spectroscopic markers to distinguish B and T cells. HPLC was the reference method for identifying carotene in T cells. RESULTS Reliable discrimination between T and B lymphocytes based on their spectral profile has been demonstrated using label-free Raman imaging and chemometric analysis. The presence of carotene in T lymphocytes (in addition to the previously reported in plasma) was confirmed and for the first time unequivocally identified as $\beta$-carotene. In addition, the molecular features of the lymphocytes nuclei were found to support the discriminant analysis. It has been shown that although the presence of carotenoids in T cells depends on individual donor variability, the reliable differentiation between lymphocytes is possible based on Raman spectra collected from individual cells. CONCLUSIONS This proves the potential of Raman spectroscopy in clinical diagnostics to automatically differentiate between cells that are an important component of our immune system.

更多信息

更多信息
种属 Human
Magnet Compatibility • EasySep™ Magnet (Catalog #18000) • “The Big Easy” EasySep™ Magnet (Catalog #18001) • Easy 50 EasySep™ Magnet (Catalog #18002) • EasyEights™ EasySep™ Magnet (Catalog #18103) • RoboSep™-S (Catalog #21000)
样本来源 Whole Blood
Selection Method Negative
Target • EasySep™ Magnet (Catalog #18000) • “The Big Easy” EasySep™ Magnet (Catalog #18001) • Easy 50 EasySep™ Magnet (Catalog #18002) • EasyEights™ EasySep™ Magnet (Catalog #18103) • RoboSep™-S (Catalog #21000)
Pathway Negative
标记抗体
质量保证:

产品仅供研究使用,不用于针对人或动物的诊断或治疗。 欲获悉更多关于STEMCELL的质控信息,请访问 STEMCELL.CN/COMPLIANCE.
Copyright © 2025 by STEMCELL Technologies. All rights reserved.