若您需要咨询产品或有任何技术问题,请通过官方电话 400 885 9050 或邮箱 info.cn@stemcell.com 与我们联系

EasySep™小鼠记忆CD4+ T细胞分选试剂盒

利用免疫磁珠负选技术,27.5分钟完成细胞分选

产品号 #(选择产品)

产品号 #19767_C

利用免疫磁珠负选技术,27.5分钟完成细胞分选

产品优势

  • 易于操作、快速
  • 纯度高达95%
  • 无需分离柱
  • 获得的活细胞无标记

产品组分包括

  • EasySep™小鼠记忆CD4+ T细胞分选试剂盒(产品号#19767)
    • EasySep™小鼠记忆CD4+ T细胞分选抗体混合物,0.5 mL
    • EasySep™ Streptavidin RapidSpheres™ 50001磁珠,2 x 1 mL
    • EasySep™ 小鼠FcR阻断剂(产品号#18730),0.2 mL
  • RoboSep™小鼠记忆CD4+ T细胞分选试剂盒(产品号#19767RF)
    • EasySep™小鼠记忆CD4+ T细胞分选抗体混合物,0.5 mL
    • EasySep™Streptavidin RapidSpheres™ 50001磁珠, 2 x 1 mL
    • EasySep™小鼠FcR阻断剂(产品号#18730),0.2 mL
    • RoboSep™ 缓冲液(产品号#20104)
    • RoboSep™过滤吸头(产品号#20125)
New format, same high quality! You may notice that your kit contents and packaging look slightly different from previous orders. We are currently updating the format of select EasySep™ Mouse kits to include a Mouse FcR blocker instead of Normal Rat Serum. With this change, all components will now be shipped in a single package, while providing the same cell isolation performance as before.
专为您的实验方案打造的产品
要查看实验方案所需的所有配套产品,请参阅《实验方案与技术文档》

总览

悬液中分选全记忆CD4+T细胞。非目的细胞可通过针对非记忆CD4+T细胞表面标志物((CD8、CD11b、CD11c、CD19、CD24、CD45R、CD45RB、CD49b、CD105及TCRγ/δ)的生物素化抗体和链霉亲和素包被的磁珠(RapidSpheres™)而被去除。

通过EasySep™磁极,将这些被磁珠标记的细胞分离,无需使用分离柱。目的细胞被简单地倾倒至新管中。

了解更多采用 RapidSphere™ 技术的下一代 EasySep™ 小鼠细胞分选试剂盒。

通过EasySep™磁极,将这些被磁珠标记的细胞分离,无需使用分离柱。目的细胞被简单地倾倒至新管中。

了解更多采用 RapidSphere™ 技术的下一代 EasySep™ 小鼠细胞分选试剂盒。

通过EasySep™磁极,将这些被磁珠标记的细胞分离,无需使用分离柱。目的细胞被简单地倾倒至新管中。

了解更多采用 RapidSphere™ 技术的下一代 EasySep™ 小鼠细胞分选试剂盒。

通过EasySep™磁极,将这些被磁珠标记的细胞分离,无需使用分离柱。目的细胞被简单地倾倒至新管中。

了解更多采用 RapidSphere™ 技术的下一代 EasySep™ 小鼠细胞分选试剂盒。

磁体兼容性
• EasySep™ Magnet (Catalog #18000) • “The Big Easy” EasySep™ Magnet (Catalog #18001) • EasyEights™ EasySep™ Magnet (Catalog #18103) • RoboSep™-S (Catalog #21000)
 
亚型
细胞分选试剂盒
 
细胞类型
T 细胞,T 细胞,CD4+
 
种属
小鼠
 
样本来源
其它细胞系,Spleen
 
筛选方法
Negative
 
应用
细胞分选
 
品牌
EasySep,RoboSep
 
研究领域
免疫
 

实验数据

Typical EasySep™ Mouse Memory CD4+ T Cell Isolation Profile

Figure 1. Typical EasySep™ Mouse Memory CD4+ T Cell Isolation Profile

Starting with mouse splenocytes, the memory CD4+ T cell (CD4+CD62L high CD44 high/int central memory and CD4+CD62L-CD44 high/int effector memory) content of the isolated fraction typically ranges from 78 - 96%. In the example above, the final purities of the start and isolated fractions are 5.3% and 90.2%, respectively.

产品说明书及文档

请在《产品说明书》中查找相关支持信息和使用说明,或浏览下方更多实验方案。

Document Type
Product Name
Catalog #
Lot #
Language
Catalog #
19767RF
Lot #
1000157900 or higher
Language
English
Catalog #
19767RF
Lot #
1000157899 or lower
Language
English
Catalog #
19767
Lot #
1000157900 or higher
Language
English
Catalog #
19767
Lot #
1000157899 or lower
Language
English
Document Type
Safety Data Sheet 1
Catalog #
19767RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Catalog #
19767RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 3
Catalog #
19767RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 4
Catalog #
19767RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 5
Catalog #
19767RF
Lot #
All
Language
English
Document Type
Safety Data Sheet 1
Catalog #
19767
Lot #
All
Language
English
Document Type
Safety Data Sheet 2
Catalog #
19767
Lot #
All
Language
English
Document Type
Safety Data Sheet 3
Catalog #
19767
Lot #
All
Language
English
Document Type
Safety Data Sheet 4
Catalog #
19767
Lot #
All
Language
English

应用领域

本产品专为以下研究领域设计,适用于工作流程中的高亮阶段。探索这些工作流程,了解更多我们为各研究领域提供的其他配套产品。

相关材料与文献

技术资料 (9)

常见问题

Can EasySep™ Streptavidin RapidSpheres™ be used for either positive or negative selection?

Currently, EasySep™ Streptavidin RapidSphere™ kits are only available for negative selection and work by targeting and removing unwanted cells.

How does the separation work?

Streptavidin RapidSphere™ magnetic particles are crosslinked to unwanted cells using biotinylated antibodies. When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a new tube.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ Streptavidin RapidSphere™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Are cells isolated using EasySep™ RapidSphere™ products FACS-compatible?

Yes. Desired cells are unlabeled and ready to use in downstream applications, such as FACS analysis.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

Can EasySep™ be used for either positive or negative selection?

Yes. The EasySep™ kits use either a negative selection approach by targeting and removing unwanted cells or a positive selection approach targeting desired cells. Depletion kits are also available for the removal of cells with a specific undesired marker (e.g. GlyA).

How does the separation work?

Magnetic particles are crosslinked to cells using Tetrameric Antibody Complexes (TAC). When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a separate fraction.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Can EasySep™ be used to isolate rare cells?

Yes. We recommend a cell concentration of 2x108 cells/mL and a minimum working volume of 100 µL. Samples containing 2x107 cells or fewer should be suspended in 100 µL of buffer.

Are the EasySep™ magnetic particles FACS-compatible?

Yes, the EasySep™ particles are flow cytometry-compatible, as they are very uniform in size and about 5000X smaller than other commercially available magnetic beads used with column-free systems.

Can the EasySep™ magnetic particles be removed after enrichment?

No, but due to the small size of these particles, they will not interfere with downstream applications.

How does the binding of the EasySep™ magnetic particle affect the cells? is the function of positively selected cells altered by the bound particles?

Hundreds of publications have used cells selected with EasySep™ positive selection kits for functional studies. Our in-house experiments also confirm that selected cells are not functionally altered by the EasySep™ magnetic particles.

If particle binding is a key concern, we offer two options for negative selection. The EasySep™ negative selection kits can isolate untouched cells with comparable purities, while RosetteSep™ can isolate untouched cells directly from whole blood without using particles or magnets.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

For positive selection, can I perform more than 3 separations to increase purity?

Yes, the purity of targeted cells will increase with additional rounds of separations; however, cell recovery will decrease.

Which cell separation kits are compatible with the EasyPlate™ EasySep™ magnet?

The EasyPlate™-compatible human EasySep™ kits are:
19051 (T Cells), 19052 (CD4 T cells), 19157 (Memory CD4 T Cells), 19053 (CD8 T Cells), 19054 (B Cells), 19254 (Naïve B cells), 19055 (NK Cells), 19058 (Monocytes without CD16 depletion), 19059 (Monocytes)

The EasyPlate™-compatible mouse EasySep™ kits are:
19751 (T Cells), 19752 (CD4 T cells), 19753 (CD8 T Cells), 19754 (B Cells), 19755 (NK Cells - please contact Tech Support)

文献 (1)

T cell-intrinsic role for Nod2 in protection against Th17-mediated uveitis. R. J. Napier et al. Nature communications 2020

Abstract

Mutations in nucleotide-binding oligomerization domain-containing protein 2 (NOD2) cause Blau syndrome, an inflammatory disorder characterized by uveitis. The antimicrobial functions of Nod2 are well-established, yet the cellular mechanisms by which dysregulated Nod2 causes uveitis remain unknown. Here, we report a non-conventional, T cell-intrinsic function for Nod2 in suppression of Th17 immunity and experimental uveitis. Reconstitution of lymphopenic hosts with Nod2-/- CD4+ T cells or retina-specific autoreactive CD4+ T cells lacking Nod2 reveals a T cell-autonomous, Rip2-independent mechanism for Nod2 in uveitis. In naive animals, Nod2 operates downstream of TCR ligation to suppress activation of memory CD4+ T cells that associate with an autoreactive-like profile involving IL-17 and Ccr7. Interestingly, CD4+ T cells from two Blau syndrome patients show elevated IL-17 and increased CCR7. Our data define Nod2 as a T cell-intrinsic rheostat of Th17 immunity, and open new avenues for T cell-based therapies for Nod2-associated disorders such as Blau syndrome.

更多信息

更多信息
种属 Mouse
Magnet Compatibility • EasySep™ Magnet (Catalog #18000) • “The Big Easy” EasySep™ Magnet (Catalog #18001) • EasyEights™ EasySep™ Magnet (Catalog #18103) • RoboSep™-S (Catalog #21000)
样本来源 Other, Spleen
Selection Method Negative
标记抗体
质量保证:

产品仅供研究使用,不用于针对人或动物的诊断或治疗。 欲获悉更多关于STEMCELL的质控信息,请访问 STEMCELL.CN/COMPLIANCE.
Copyright © 2025 by STEMCELL Technologies. All rights reserved.